WORKSHEET
| Code: (A) | (B) | (C) | (D) | (E) | (F) |
| Cooling Equipment Efficiency (From Table X) |
Heating Equipment Efficiency (From Table X) |
Cooling Fuel Price $/Million BTU |
Heating Fuel Price $/Million BTU |
Cooling Energy Cost $/Million BTU [C÷A] |
Heating Energy Cost $/Million BTU [D÷B] |
For fuel prices:
Electricity: $/million BTU = ¢/KWH x 2.93
Natural Gas: $/million BTU = ($/therm or $/CCF) x 10
Fuel Oil: $/million BTU = $/gal. x 7.15
| Code: (1) | (2) | (3) | (4) | (5) | (6) | (7) |
| Ceiling Area, Square Feet | Cooling Load Factor (From Table Y) |
Heating Load Factor (From Table Y) |
Annual Cooling Savings, $/yr [(1) x (2) x E] ÷ 1,000,000 |
Annual Heating Savings, $/yr [(1) x (3) x F]÷ 1,000,000 |
Total Energy Savings, $/yr [(4)+(5)] |
Cost for RB or Insulation, $ |
| Code: (8) | (9) | (10) | (11) | (12) |
| Cooling Discount Factor (From Table Z) |
Heating Discount Factor (From Table Z) |
Present Value Cooling Savings, $ [(4) x (8)] |
Present Value Heating Savings, $ [(5) x (9)] |
Total Present Value Energy Savings, $ [(10) + (11)] |